АвтомобилиАстрономияБиологияГеографияДом и садДругие языкиДругоеИнформатикаИсторияКультураЛитератураЛогикаМатематикаМедицинаМеталлургияМеханикаОбразованиеОхрана трудаПедагогикаПолитикаПравоПсихологияРелигияРиторикаСоциологияСпортСтроительствоТехнологияТуризмФизикаФилософияФинансыХимияЧерчениеЭкологияЭкономикаЭлектроника






Microprocessor Based Relays






Electroomagnetic Relays

· EMrS consist of an input coil that’s wound to accept a particular voltage signal, plus a set of one or more contacts that rely on an armature(or lever) activated by the energized coil to open or close an electrical circuit.

Solid-state Relays(SSRs)

· SSRs use semiconductor output instead of mechanical contacts to switch the circuit. The output device is optically-coupled to an LED light source inside the relay. The relay is turned on by energizing this LED, usually with low-voltage DC power.

Microprocessor Based Relays

Use in power system monitoring and protection.Microprocessor for switching mechanism. Commonly used

 

Advantages\Disadvantages

Electromagnetic Relays(EMRs)

· Simplicity

· Not expensive

· Mechanical Wear

Solid –state Relays(SSRs)

· No Mechanical movements

· Faster than EMR

· No sparking between contacts

Microprocessor-based Relay

· Much Higher precision and more reliable and durable

· Improve the reliability and power quality of electrical power systems before< during and after faults occur.

· Capable of both digital and analog I\O.

· Higher cost.

4 Какие типы релейной защиты вы знаете? Преимущества \ DisadvantagesE

1. Electroomagnetic Реле

• EMRs состоят из входной катушки, которая намотана на прием определенного сигнала напряжения, а также набор из одного или более контактов, которые полагаются на арматуре (или рычаг), включаемого под напряжением катушки, чтобы открыть или закрыть электрическую цепь.

2. Твердотельные реле (SSRS)

• SSRs использовать полупроводниковый выход вместо механических контактов для переключения цепи. Устройство вывода оптически соединенный с источником света СИД внутри реле. Реле включается подачей питания этот светодиод, как правило, с низким уровнем напряжения питания постоянного тока.

3. Реле микропроцессорный

Использование в мониторинге системы питания и protection.Microprocessor для механизма переключения. Обычно используется

Преимущества недостатки

Электромагнитные реле (ЭМЗ)

• Простота

• Недорогой

• механический износ

Твердые -state Реле (SSRS)

• Отсутствие механических движений

• Быстрее, чем ЭМИ

• Отсутствие искрения между контактами

Микропроцессорные реле

• Значительно Более высокая точность и более надежны и долговечны

• Повышение качества и надежности мощность систем электроснабжения до < во время и после того, как из-за неисправности.

• Возможность цифровых и аналоговых сигналов I \ O.

• Более высокая стоимость.

5 What Components(Equipment) Do We Protect?

· Generators

· Transformers, Reactors

· Lines

· Buses

· Capacitors

5 Какие компоненты (оборудование) мы защищаем?

• Генераторы

• Трансформаторы, Реакторы

• линии

• Автобусы

• Конденсаторы

6 Main components of protection systems?

1. Current & Voltage Transformer: also called instrument transformers.Their purpose is to step down the current or voltage of a device to measurable values, within the instrumentation measurement range 5 A or 1A in the case of a current transformers(CTs), and 110V or 100V in the case of a voltage(or potential) transformers (VTs/PTs). Hence, protective equipment inputs are standardized within the ranges above.

2. Protective relays: are intelligent electronic devices (IEDs) which receive measured signals from the secondary side of CTs and VTs and detect whether the protected unit is in a stressed condition(based on their type and configuration) or not. A ttrip signal is sent by protective relays to the circuit breakers to disconnect the faulty components from power system if necessary.

3. Circuit Breakers: Circuit Breakers act upon open commands sent by protective relays when faults are detected and close commands when faults are cleared. Hey can also be manually opened, for example, to isolate a component for maintenance.

4. Communication Channels: are the paths that deliver information and measurements from an initiating relay at one location to a receiving relay(or substation) at another location.

6 Основные компоненты системы защиты?

1. Ток и напряжение Трансформатор: также называется инструмент трансформаторы.ИХ цель состоит в том, чтобы уйти в отставку тока или напряжения прибора для измеряемых величин, в пределах диапазона измерительных приборов 5 A или 1A в случае трансформаторов тока (ТТ) и 110V или 100В в случае напряжения (или потенциальных) трансформаторов (VTS / PTS). Следовательно, защитные входы оборудования стандартизованы в пределах вышеуказанных диапазонов.

2. Защитные реле: это интеллектуальные электронные устройства (СВУ), которые получают измеренные сигналы от вторичной обмотки трансформаторов тока и напряжения и обнаружить ли защищенный аппарат находится в стрессовом состоянии (в зависимости от их типа и конфигурации), или нет. Сигнал отключение передается реле защиты для автоматических выключателей, чтобы отключить неисправные компоненты от системы электропитания, если это необходимо.

3. Автоматические выключатели: Автоматические выключатели действуют на открытых команд, посылаемых с помощью реле защиты при обнаружении ошибок и закрытия команды, когда ошибки будут удалены. Эй может также быть вручную открыт, например, чтобы выделить компонент для технического обслуживания.

4. Каналы связи: это пути, которые обеспечивают информацию и измерения от реле инициирующей в одном месте в приемное реле (или подстанции) в другом месте.

7 The five basic facets(requirements)?

1. Reliability: assurance that the protection will perform correctly.

2. Selectivity: maximum continuity of service with minimum system disconnection.

3. Speed of operation: minimum fault duration and consequent equipment damage.

4. Simplicity: minimum protective equipment and associated circuitry to achieve the protection objectives.

5. Economics: maximum protection at minimal total cost.

Because these are the underlying foundation of all protection.

7 Пять основных аспектов (требований)?

1. Надежность: гарантия того, что защита будет работать некорректно.

2. Избирательность: максимальная непрерывность обслуживания с минимальным отключением системы.

3. Скорость работы: минимальная продолжительность неисправности и последующее повреждение оборудования.

4. Простота: минимальное защитное оборудование и связанные с ними схемы для достижения целей защиты.

5. Экономика: максимальная защита при минимальной совокупной стоимости.

Поскольку это основной фундамент всякой защиты.






© 2023 :: MyLektsii.ru :: Мои Лекции
Все материалы представленные на сайте исключительно с целью ознакомления читателями и не преследуют коммерческих целей или нарушение авторских прав.
Копирование текстов разрешено только с указанием индексируемой ссылки на источник.